NSN: 5925-00-877-6763
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Surface To Terminal End Distance
2.490 inches nominal
-
Pole Quantity
2
-
Mounting Facility Type And Quantity
4 threaded hole
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 50.0 dc
-
Circuit Protection Type
overcurrent
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
Internal Trip Release Configuration
series trip
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct and 9.000 maximum at 200 pct
-
Unpackaged Unit Weight
8.750 ounces
-
Thread Series Designator
unc
-
Center To Center Distance Between Terminals Parallel To Width
0.760 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Boss Height
0.140 inches nominal
-
Body Length
2.530 inches maximum
-
Body Width
1.220 inches nominal
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
-
Arc Quenching Method
magnetic blowout
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac and 15.0 amperes dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 2000.0 dc
-
Trip Release Method
magnetic-hydraulic
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
2 toggle
-
External Actuator Linkage Arrangement
one and two linked
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Frequency In Hertz
60.0
-
Terminal Type And Quantity
4 threaded stud