  • Body Length

    10.000 inches nominal

  • Body Height

    3.938 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.203 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    8.625 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    20

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0

  • Nominal Thread Size

    0.250 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    300.000 nominal at 150 pct and 110.000 nominal at 200 pct and 40.000 nominal at 300 pct

  • Body Style

    multipole-single actuator type

  • Body Width

    4.500 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    8.625 inches nominal

  • Boss Height

    0.250 inches nominal

  • Pole Quantity

    3

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac

  • Circuit Protection Type

    overcurrent

  • Terminal Type And Quantity

    6 compression

  • Frequency In Hertz

    60.0

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal

  • Internal Trip Release Configuration

    relay trip

  • Actuator Position Designation

    at pole two

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Trip Release Characteristic

    instantaneous and time delay

  • Trip Release Method

    thermal-magnetic

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    general purpose

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...