NSN: 5925-00-878-4072

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    11b multipole-single actuator type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    5.125 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.500 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Body Length

    6.000 inches nominal

  • Body Width

    3.000 inches nominal

  • Body Height

    3.594 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.594 inches nominal

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    7500.0 ac and

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Function

    trip-reset

  • Frequency In Hertz

    60.0 all locations

  • Boss Height

    0.219 inches nominal

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes ac and

  • Maximum Continuous Load Current Rating Per Pole

    100.0 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Iii Unpackaged Unit Weight

    13.000 ounces

  • Terminal Type And Quantity

    4 compression

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...