NSN: 5925-00-890-9296

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Width

    0.640 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and 0.906 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.700 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.500 minimum at 200 pct and 8.000 maximum at 200 pct

  • Switch Terminal Type

    pin

  • Frequency In Hertz

    400.0

  • Test Data Document

    05869-711520 drawing

  • Terminal Type And Quantity

    2 wire hook

  • Body Style

    single pole type

  • Bushing Length

    0.300 inches minimum and 0.320 inches maximum

  • Body Length

    1.760 inches maximum

  • Case Material

    metal

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    750.0 milliamperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac

  • Trip Release Method

    magnetic

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.375 inches

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shockproof and vibrationproof and corrosion resistant and moisture resistant

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Unpackaged Unit Weight

    1.800 ounces

  • Thread Series Designator

    unef

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.