NSN: 5925-00-899-6427

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Body Width

    8.250 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.125 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Body Height

    4.062 inches nominal

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Arc Quenching Method

    deion

  • Manual Actuator Type And Quantity

    1 toggle

  • Center To Center Distance Between Terminals Parallel To Length

    9.125 inches nominal

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    250.0 amperes ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.750 inches nominal

  • Body Length

    10.125 inches nominal

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Storage Type

    general purpose warehouse

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    2.750 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    80.000 minimum at 200 pct all locations and 590.000 maximum at 200 pct all locations

  • Unthreaded Mounting Hole Diameter

    0.562 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...