Technical Characteristics

  • Body Width

    2.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Boss Height

    0.140 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    external at each pole

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    2.5 ac

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    2.500 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.300 minimum at 200 pct and 0.900 maximum at 200 pct all locations

  • Terminal Type And Quantity

    6 threaded stud

  • Thread Series Designator

    unc

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Frequency In Hertz

    60.0

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...