Technical Characteristics

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Width

    1.485 inches minimum and 1.515 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Test Data Document

    05869-711570 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations and 50.0 dc all locations

  • Switch Voltage Rating And Type In Volts

    115.0 ac and 50.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations and 2000.0 dc all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct all locations and 10.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant and moisture resistant and salt spray proof

  • Nominal Thread Size

    0.138 inches

  • Body Length

    2.485 inches minimum and 2.515 inches maximum

  • Frequency In Hertz

    60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Boss Height

    0.125 inches minimum and 0.155 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Manual Actuator Type And Quantity

    2 toggle

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Mounting Surface To Terminal End Distance

    2.583 inches minimum and 2.763 inches maximum

  • Terminal Type And Quantity

    4 threaded stud

  • External Actuator Linkage Arrangement

    one and two linked

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Pole Quantity

    2

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations and 2.0 amperes dc all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.047 inches minimum and 2.077 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Unpackaged Unit Weight

    0.547 pounds

  • Trip Release Method

    magnetic all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.