NSN: 5925-00-905-9324

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    70.000 minimum at 200 pct all locations and 200.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    general purpose

  • Trip Release Ambient Temp Rating

    40.0 deg celsius maximum all locations

  • Packaged Unit Weight

    7.500 pounds

  • Body Style

    13b multipole-single actuator type

  • Case Material

    plastic

  • Unthreaded Mounting Hole Diameter

    0.219 inches nominal

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Features Provided

    adjustable trip release

  • Maximum Continuous Load Current Rating Per Pole

    225.0 amperes ac all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Body Length

    9.500 inches nominal

  • Body Width

    4.125 inches nominal

  • Body Height

    4.062 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    8.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.250 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Boss Height

    0.250 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    22000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    instantaneous all locations and time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Adjustable Trip Setting Current Range Per Pole In Amps

    1300.0 to 2250.0 ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...