Technical Characteristics

  • Reset Method

    manual

  • Ultimate Trip Time Per Pole In Seconds

    4.000 minimum and 40.000 maximum single location

  • Trip Release Method

    magnetic single location

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.605 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Body Width

    0.640 inches nominal

  • Body Length

    1.531 inches nominal

  • Bushing Length

    0.340 inches nominal

  • Body Style

    2a single pole type

  • Reference Number Differentiating Characteristics

    as differentiated by special test features

  • Thread Series Designator

    unef

  • Manufacturers Code

    10001

  • Special Test Features

    navord od36190

  • Nominal Thread Size

    0.375 inches

  • Actuator Position Designation

    at pole one

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    2 wire hook

  • Design Control Reference

    2258974p19

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct and 6.000 maximum at 200 pct and 0.085 minimum at 300 pct and 1.800 maximum at 300 pct and 0.015 minimum at 400 pct and 0.600 maximum at 400 pct single location

  • Internal Trip Release Configuration

    series trip single location

  • Actuator Function

    reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc single location

  • Case Material

    metal

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...