NSN: 5925-00-923-2411
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
reset
-
Internal Trip Release Configuration
series trip
-
Thread Series Designator
unc
-
Terminal Type And Quantity
2 screw
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0
-
Trip Release Characteristic
instantaneouss and time delay
-
Trip Release Method
magnetic
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes dc
-
Thread Quantity Per Inch
32
-
Case Material
plastic
-
Pole Quantity
1
-
Mounting Facility Type And Quantity
2 threaded hole
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 dc
-
Circuit Protection Type
overcurrent
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.300 minimum at 150 pct and 1.250 maximum at 150 pct and 0.130 minimum at 200 pct and 0.140 maximum at 200 pct and 0.050 minimum at 300 pct and 0.130 maximum at 300 pct and 0.030 minimum at 400 pct and 0.080 maximum at 400 pct