NSN: 5925-00-923-3760

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    6 wire hook

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Body Length

    1.495 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Switch Contact Arrangement

    single pole, double throw

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.678 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Nominal Thread Size

    0.375 inches

  • Switch Location And Position Designation

    internal at pole three

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct and 0.500 maximum at 200 pct all locations

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Internal Trip Release Configuration

    series trip all locations

  • Body Style

    1b multipole-single actuator type

  • Bushing Length

    0.375 inches nominal

  • Body Width

    1.872 inches nominal

  • Case Material

    metal

  • Iii Arc Quenching Method

    magnetic blowout

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    1.25 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Auxiliary Switch Function And Quantity

    1 control

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Switch Current Rating And Type In Amps

    1.0 ac and 0.5 dc

  • Frequency In Hertz

    400.0 all locations

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...