NSN: 5925-00-925-5097
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 all locations
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 minimum at 200 pct all locations and 5.000 maximum at 200 pct all locations
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac second location
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Precious Material
silver
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Length
1.562 inches maximum
-
Bushing Length
0.365 inches minimum and 0.390 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Thread Series Designator
unef
-
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac first location
-
Terminal Type And Quantity
6 wire hook
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations
-
Mounting Surface To Terminal End Distance
1.828 inches maximum
-
Internal Trip Release Configuration
series trip all locations
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed and moisture resistant
-
Precious Material And Location
contact surfacescpl-1bjab5.0 silver
-
Unpackaged Unit Weight
4.500 ounces
-
Actuator Position Designation
at pole two
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Center To Center Distance Between Terminals Parallel To Length
0.865 inches minimum and 0.885 inches maximum
-
Manual Actuator Type And Quantity
1 toggle
-
Body Width
1.937 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac third location