NSN: 5925-00-937-1828

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    1

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 nominal at 200 pct single location

  • Inclosure Protection Type For Which Designed

    general purpose

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Frequency In Hertz

    60.0 or 400.0 single location

  • Thread Series Designator

    uns

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac and 28.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push button

  • Actuator Function

    trip-reset

  • Case Material

    plastic

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac and 7.5 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac and 2000.0 dc single location

  • Trip Release Method

    thermal single location

  • Trip Release Characteristic

    time delay single location

  • Reset Method

    manual

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.469 inches

  • Iii Unpackaged Unit Weight

    29.0 grams

  • Terminal Type And Quantity

    2 screw

  • Body Style

    1a single pole type

  • Bushing Length

    0.250 inches nominal

  • Body Length

    0.750 inches nominal

  • Body Width

    0.562 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.703 inches nominal

  • Iii Nonturn Device Location

    at 12 oclock

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.707 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...