NSN: 5925-00-937-2007
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
4.609 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
3.062 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.359 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac
-
Circuit Protection Type
overcurrent
-
Trip Release Method
magnetic-hydraulic
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Ultimate Trip Time Per Pole In Seconds
1.700 minimum and 7.500 maximum
-
Reset Method
manual
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole two
-
Auxiliary Switch Function And Quantity
1 control
-
Nominal Thread Size
0.164 inches
-
Switch Current Rating And Type In Amps
15.0 ac
-
Switch Voltage Rating And Type In Volts
125.0 ac
-
Terminal Type And Quantity
4 threaded stud
-
Body Width
2.000 inches nominal
-
Case Material
plastic
-
Switch Contact Arrangement
single pole,double throw
-
Boss Height
0.219 inches nominal
-
Mounting Surface To Terminal End Distance
3.463 inches nominal
-
Pole Quantity
2
-
Mounting Facility Type And Quantity
4 threaded hole
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 125.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac and 5000.0 dc
-
Main Contact Tripping Mechanism Type
trip free
-
Internal Trip Release Configuration
series trip
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.800 minimum at 150 pct and 2.800 maximum at 150 pct and 0.350 minimum at 200 pct and 1.000 maximum at 200 pct and 0.150 minimum at 300 pct and 0.380 maximum at 300 pct
-
Switch Terminal Type
threaded stud
-
Frequency In Hertz
60.0
-
Thread Series Designator
unc