NSN: 5925-00-941-2145

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nominal Thread Size

    0.138 inches

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    3 toggle

  • Trip Release Characteristic

    time delay all locations

  • Iii Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Pole Quantity

    3

  • Boss Height

    0.140 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Case Material

    plastic

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    explosion resistant and fungus resistant and moisture resistant

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Position Designation

    at each pole

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Time Per Pole In Seconds

    60.000 minimum and 302.000 maximum all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Body Width

    2.250 inches nominal

  • Body Length

    2.500 inches nominal

  • Body Style

    8c multipole-multiple actuator type

  • Terminal Type And Quantity

    6 threaded stud

  • Frequency In Hertz

    400.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct and 80.000 maximum at 200 pct all locations

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...