NSN: 5925-00-949-8579

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Unpackaged Unit Weight

    0.875 pounds

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc first location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac third location

  • Maximum Continuous Load Current Rating Per Pole

    400.0 milliamperes dc first location

  • Maximum Continuous Load Current Rating Per Pole

    32.0 amperes ac third location

  • Maximum Continuous Load Current Rating Per Pole

    32.0 amperes ac second location

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Arc Quenching Method

    magnetic blowout

  • Pole Quantity

    3

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Thread Series Designator

    unc

  • Frequency In Hertz

    60.0 third location

  • Frequency In Hertz

    60.0 second location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct all locations and 0.500 maximum at 200 pct

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    3 toggle

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac second location

  • Special Handling Feature

    magnetic

  • Mounting Surface To Terminal End Distance

    2.549 inches minimum and 2.673 inches maximum

  • Boss Height

    0.140 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Body Width

    2.250 inches nominal

  • Body Length

    2.500 inches nominal

  • Body Style

    8c multipole-multiple actuator type

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...