NSN: 5925-00-954-1725

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Main Contact Tripping Mechanism Type

    trip free

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc

  • Trip Release Method

    magnetic

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    between pole one and two

  • Nominal Thread Size

    0.375 inches

  • Unpackaged Unit Weight

    3.600 ounces

  • Thread Series Designator

    unef

  • Body Length

    1.562 inches maximum

  • Case Material

    metal

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Nonturn Device Radius

    0.610 inches minimum and 0.640 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Thread Pitch Diameters

    p0.3503/p0.3537 inches

  • Bushing Length

    0.380 inches maximum

  • Body Width

    1.281 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.860 inches minimum and 0.890 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.610 inches minimum and 0.640 inches maximum

  • Nonturn Device Diameter

    0.235 inches minimum and 0.265 inches maximum

  • Pole Quantity

    2

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    350.0 milliamperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc

  • Circuit Protection Type

    overcurrent

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    relay trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.060 minimum at 200 pct and 0.600 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof and hermetically sealed

  • Terminal Type And Quantity

    4 tab,solder lug and 4 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...