NSN: 5925-00-957-0467
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Width
2.990 inches minimum and 3.010 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac first location
-
Body Length
5.240 inches minimum and 5.260 inches maximum
-
Unthreaded Mounting Hole Diameter
0.190 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac second location
-
Terminal Type And Quantity
4 threaded stud
-
Center To Center Distance Between Terminals Parallel To Width
0.974 inches minimum and 0.994 inches maximum
-
Auxiliary Switch Function And Quantity
1 control
-
Case Material
plastic
-
Boss Height
0.208 inches minimum and 0.228 inches maximum
-
Storage Type
general purpose warehouse
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.052 inches minimum and 3.072 inches maximum
-
Actuator Function
trip-reset
-
Mounting Facility Type And Quantity
4 threaded hole and 4 unthreaded hole
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac first location
-
Circuit Protection Type
overcurrent second location
-
Body Height
2.677 inches minimum and 2.697 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac second location
-
Thread Quantity Per Inch
32
-
Internal Trip Release Configuration
series trip first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac second location
-
Circuit Protection Type
overcurrent first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location
-
Reset Method
manual
-
Thread Series Designator
unc
-
Switch Terminal Type
threaded stud
-
Pole Quantity
3
-
Fragility Factor
moderately rugged
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.974 inches minimum and 0.994 inches maximum
-
Trip Release Method
magnetic-hydraulic second location
-
Center To Center Distance Between Terminals Parallel To Length
4.349 inches minimum and 4.369 inches maximum
-
Nominal Thread Size
0.164 inches
-
Arc Quenching Method
magnetic blowout
-
Trip Release Method
magnetic-hydraulic first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
100.000 maximum at 200 pct first location
-
Main Contact Tripping Mechanism Type
trip free
-
Inclosure Protection Type For Which Designed
dustproof and fungus proof
-
Switch Location And Position Designation
external at pole three
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 second location
-
Trip Release Characteristic
time delay second location
-
Frequency In Hertz
60.0 all locations
-
Manual Actuator Type And Quantity
1 toggle
-
Special Features
pole three is a switch only
-
Internal Trip Release Configuration
series trip second location
-
Body Style
multipole-single actuator type
-
Switch Contact Arrangement
single pole, double throw
-
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 minimum at 200 pct second location and 30.000 minimum at 200 pct first location and 100.000 maximum at 200 pct second location
-
Actuator Position Designation
at pole two
-
Trip Release Characteristic
time delay first location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 first location