NSN: 5925-00-957-1932

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    9.000 minimum at 200 pct all locations and 70.000 maximum at 200 pct all locations

  • Frequency In Hertz

    400.0 all locations

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Manual Actuator Type And Quantity

    3 toggle

  • Unpackaged Unit Weight

    11.100 ounces

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Fragility Factor

    moderately rugged

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac all locations

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Thread Quantity Per Inch

    32

  • Inclosure Protection Type For Which Designed

    shock resistant and salt spray proof and fungus resistant and moisture resistant and vibration resistant

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    2.491 inches maximum

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Width

    2.265 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...