NSN: 5925-00-964-7901
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency In Hertz
60.0 single location
-
Thread Series Designator
unef
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 32.0 dc single location
-
Body Width
0.560 inches nominal
-
Bushing Length
0.500 inches nominal
-
Thread Quantity Per Inch
28
-
Case Material
plastic
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
120.0 single location
-
Actuator Function
reset
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.100 minimum at 200 pct single location and 1.000 maximum at 200 pct single location
-
Storage Type
general purpose warehouse
-
Inclosure Protection Type For Which Designed
explosion resistant
-
Manual Actuator Type And Quantity
1 push button
-
Body Length
1.380 inches nominal
-
Nominal Thread Size
0.438 inches
-
Maximum Continuous Load Current Rating Per Pole
375.0 milliamperes ac single location and 375.0 milliamperes dc single location
-
Circuit Protection Type
overcurrent single location
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Mounting Surface To Terminal End Distance
1.660 inches nominal
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
750.0 ac single location and 750.0 dc single location
-
Trip Release Characteristic
time delay single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Center To Center Distance Between Terminals Parallel To Length
0.840 inches nominal
-
Terminal Type And Quantity
2 tab, solder lug
-
Body Style
single pole type
-
Trip Release Method