NSN: 5925-00-975-7105
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Nominal Thread Size
0.138 inches
-
Inclosure Protection Type For Which Designed
hermetically sealed and shock resistant and vibration resistant
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
-
Iii Unpackaged Unit Weight
4.400 ounces
-
Thread Series Designator
unc
-
Thread Pitch Diameters
0.1177 to 0.1214 inches
-
Body Length
2.000 inches nominal
-
Body Width
1.515 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Boss Height
0.130 inches nominal
-
Mounting Surface To Terminal End Distance
2.000 inches maximum
-
Iii Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
4 threaded hole
-
Iii Special Handling Feature
magnetic
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Trip Release Characteristic
time delay all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
at pole one
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct all locations
-
Frequency In Hertz
50.0 or 60.0 all locations
-
Terminal Type And Quantity
4 quick disconnect, male
-
Body Style
17b multipole-single actuator type
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Iii Fragility Factor
moderately rugged
-
Pole Quantity
2
-
Iii Storage Type
general purpose warehouse
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac all locations
-
Circuit Protection Type
overcurrent all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Reset Method
manual
-
Actuator Function
trip-reset