NSN: 5925-00-985-8276

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    shockproof and vibrationproof

  • Unpackaged Unit Weight

    154.0 grams

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Body Height

    1.875 inches nominal

  • Frequency In Hertz

    400.0 all locations

  • Trip Release Ambient Temp Rating

    125.0 deg celsius nominal all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations

  • Body Width

    2.063 inches nominal

  • Body Length

    1.300 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.688 inches nominal

  • Nominal Thread Size

    0.469 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Thread Series Designator

    uns

  • Case Material

    plastic

  • Trip Release Method

    thermal all locations

  • Terminal Type And Quantity

    6 threaded stud

  • Bushing Length

    0.250 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.750 inches nominal

  • Precious Material And Location

    contacts silver

  • Reset Method

    manual

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Arc Quenching Method

    air

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...