  • Storage Type

    unimproved open

  • Terminal Type And Quantity

    2 screw

  • Actuator Function

    trip-reset

  • Body Width

    0.750 inches nominal

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Thread Series Designator

    unc

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic-hydraulic single location

  • Body Style

    single pole type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 300 pct single location and 1.200 maximum at 200 pct single location and 0.400 minimum at 200 pct single location and 0.400 maximum at 300 pct single location

  • Body Length

    2.500 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.190 inches nominal

  • Inclosure Protection Type For Which Designed

    explosion proof

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Mounting Surface To Terminal End Distance

    2.000 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac single location

  • Pole Quantity

    1

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Ultimate Trip Time Per Pole In Seconds

    0.800 minimum single location and 3.500 maximum single location

  • Case Material

    plastic

  • Frequency In Hertz

    60.0 single location

  • Unpackaged Unit Weight

    4.250 ounces

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.