NSN: 5925-00-989-9633

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location

  • Body Length

    3.219 inches nominal

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    150.0 milliamperes ac single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Unthreaded Mounting Hole Diameter

    0.140 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    1 threaded hole and 1 unthreaded hole

  • Boss Height

    0.125 inches nominal

  • Body Height

    2.656 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location

  • Body Style

    single pole type

  • Ultimate Trip Time Per Pole In Seconds

    1.550 minimum single location and 7.000 maximum single location

  • Frequency In Hertz

    60.0 single location

  • Mounting Slot Width

    0.164 inches nominal

  • Trip Release Characteristic

    instantaneous single location and time delay single location

  • Center To Center Distance Between Terminals Parallel To Length

    2.375 inches nominal

  • Body Width

    1.469 inches nominal

  • Case Material

    plastic

  • Trip Release Method

    magnetic single location

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.375 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.350 minimum at 200 pct single location and 1.000 maximum at 200 pct single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...