Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac and 250.0 dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac and 10000.0 dc

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Time Per Pole In Seconds

    600.000 minimum and 10000.000 maximum

  • Reset Method

    manual

  • Trip Delay Time In Seconds Per Rated Continuous Current

    160.000 minimum at 200 pct and 290.000 maximum at 200 pct

  • Unthreaded Mounting Hole Diameter

    0.228 inches nominal

  • Pole Quantity

    3

  • Maximum Continuous Load Current Rating Per Pole

    150.0 amperes ac and 150.0 amperes dc

  • Trip Release Method

    thermal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal

  • Terminal Type And Quantity

    6 bus bar

  • Case Material

    plastic

  • Mounting Facility Type And Quantity

    4 unthreaded hole

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...