NSN: 5925-00-994-0494

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    5a single pole type

  • Overall Length

    2.283 inches nominal

  • Overall Width

    0.452 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.653 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.137 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.970 inches nominal

  • Boss Height

    0.130 inches nominal

  • Mounting Surface To Terminal End Distance

    1.807 inches nominal

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    200.0 ac single location and 200.0 dc

  • Actuator Function

    reset

  • Trip Release Ambient Temp Rating

    68.0 deg fahrenheit nominal single location

  • Unpackaged Unit Weight

    1.500 ounces

  • Pole Quantity

    1

  • Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location and 65.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal-magnetic single location

  • Trip Release Characteristic

    instantaneous single location and time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push button

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    9.000 minimum at 200 pct single location and 60.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Frequency In Hertz

    60.0 single location

  • Terminal Type And Quantity

    2 quick disconnect, male

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...