Technical Characteristics

  • Mounting Surface To Terminal End Distance

    1.690 inches minimum and 1.710 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Terminal Type And Quantity

    6 wire hook

  • Ultimate Trip Time Per Pole In Seconds

    0.700 minimum all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.615 inches minimum and 0.635 inches maximum

  • Thread Series Designator

    unef

  • Inclosure Protection Type For Which Designed

    dustproof and explosion proof and fungus resistant and moisture resistant and vibrationproof

  • Frequency In Hertz

    400.0 all locations

  • Body Style

    single pole type

  • Bushing Length

    0.365 inches minimum and 0.385 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    75.0 milliamperes ac all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Center To Center Distance Between Terminals Parallel To Length

    0.865 inches minimum and 0.885 inches maximum

  • Case Material

    metal

  • Body Length

    1.552 inches minimum and 1.572 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 nominal at 150 pct all locations and 0.035 nominal at 300 pct all locations and 0.150 nominal at 200 pct all locations and 0.004 nominal at 1000 pct all locations

  • Actuator Position Designation

    at pole two

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Mounting Facility Type And Quantity

    thd bushing

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Body Width

    1.844 inches minimum and 1.906 inches maximum

  • Storage Type

    general purpose warehouse

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Fragility Factor

    moderately rugged

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...