NSN: 5925-01-008-2399

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nominal Thread Size

    0.138 inches

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    3 toggle

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    208.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations

  • Pole Quantity

    3

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.190 inches nominal

  • Case Material

    plastic

  • Body Width

    2.250 inches nominal

  • Bushing Length

    0.130 inches nominal

  • Terminal Type And Quantity

    6 screw

  • Thread Series Designator

    unc

  • Frequency In Hertz

    60.0 all locations

  • Inclosure Protection Type For Which Designed

    explosion proof

  • Trip Delay Time In Seconds Per Rated Continuous Current

    12.000 minimum at 200 pct and 110.000 maximum at 200 pct all locations

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Position Designation

    at each pole

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Thread Quantity Per Inch

    32

  • Iii Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Mounting Surface To Terminal End Distance

    2.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.810 inches nominal

  • Body Length

    2.500 inches nominal

  • Body Style

    1c multipole-multiple actuator type

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...