NSN: 5925-01-016-5144

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    5.844 inches nominal

  • Body Width

    6.192 inches nominal

  • Body Height

    2.577 inches minimum and 2.641 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Switch Contact Arrangement

    single pole,double throw

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.218 inches nominal

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 slot

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    400.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    300.0 dc

  • Trip Release Characteristic

    instantaneouss

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.164 inches

  • Switch Current Rating And Type In Amps

    0.25 dc

  • Switch Voltage Rating And Type In Volts

    50.0 dc

  • Unpackaged Unit Weight

    2.250 pounds

  • Internal Trip Release Configuration

    series trip

  • Switch Location And Position Designation

    internal at pole one

  • Inclosure Protection Type For Which Designed

    dustproof

  • Switch Terminal Type

    tab,solder lug

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 screw

  • Mounting Slot Width

    0.164 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.546 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    200.0 amperes dc

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc

  • Circuit Protection Type

    overcurrent

  • Trip Release Method

    magnetic

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0

  • Main Contact Tripping Mechanism Type

    trip free

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...