NSN: 5925-01-020-9498

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    5.219 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.225 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Iii Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and 250.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac and 10000.0 dc all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    11.000 minimum at 200 pct and 35.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Trip Release Ambient Temp Rating

    50.0 deg celsius nominal all locations

  • Body Style

    11b multipole-single actuator type

  • Body Length

    6.062 inches nominal

  • Body Width

    4.125 inches nominal

  • Body Height

    3.406 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.125 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Boss Height

    0.250 inches nominal

  • Pole Quantity

    3

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac and 20.0 amperes dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...