Technical Characteristics

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Frequency In Hertz

    40.0

  • Terminal Type And Quantity

    4 compression

  • Body Height

    3.156 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    5.125 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.500 inches nominal

  • Pole Quantity

    2

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac and 70.0 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac and 250.0 dc all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Body Style

    11b multipole-single actuator type

  • Body Length

    6.000 inches nominal

  • Body Width

    4.469 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    3.000 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    5.125 inches nominal

  • Boss Height

    0.125 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac and 10000.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Release Characteristic

    instantaneous and time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    between pole one and two

  • Trip Delay Time In Seconds Per Rated Continuous Current

    30.000 minimum at 200 pct and 100.000 maximum at 200 pct all locations

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...