NSN: 5925-01-025-9079

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Nonturn Device Length

    0.063 inches minimum and 0.125 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Inclosure Protection Type For Which Designed

    vibrationproof and shockproof and hermetically sealed

  • Thread Series Designator

    unef

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and 0.906 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.085 minimum at 200 pct all locations and 0.600 maximum at 200 pct all locations

  • Body Width

    1.875 inches maximum

  • Terminal Type And Quantity

    6 wire hook

  • Bushing Length

    0.380 inches maximum

  • Nonturn Device Diameter

    0.109 inches minimum and 0.171 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac second location

  • Reset Method

    manual

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes dc third location

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations and 1000.0 dc all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Nonturn Device Radius

    0.594 inches minimum and 0.656 inches maximum

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Actuator Position Designation

    at pole two

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Body Length

    1.500 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac first location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...