NSN: 5925-01-027-2018

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 slot

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 screw

  • Body Style

    5c multipole-multiple actuator type

  • Center To Center Distance Between Terminals Parallel To Width

    0.994 inches minimum and 1.058 inches maximum

  • Boss Height

    0.187 inches minimum and 0.251 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Mounting Slot Width

    0.164 inches nominal

  • Body Length

    5.768 inches minimum and 5.832 inches maximum

  • Body Width

    3.046 inches minimum and 3.110 inches maximum

  • Body Height

    2.577 inches minimum and 2.641 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.515 inches minimum and 3.579 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.718 inches minimum and 2.782 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.994 inches minimum and 1.058 inches maximum

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Maximum Continuous Load Current Rating Per Pole

    192.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct and 0.800 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Frequency In Hertz

    60.0

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...