NSN: 5925-01-028-5188
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
multipole-single actuator type
-
Bushing Length
0.365 inches minimum and 0.385 inches maximum
-
Body Length
1.552 inches minimum and 1.572 inches maximum
-
Body Width
1.271 inches minimum and 1.291 inches maximum
-
Case Material
metal
-
Center To Center Distance Between Terminals Parallel To Length
0.865 inches minimum and 0.885 inches maximum
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
1.690 inches minimum and 1.710 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Trip Release Method
magnetic-hydraulic
-
Trip Release Characteristic
time delay
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Position Designation
between pole one and two
-
Nominal Thread Size
0.375 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.300 minimum at 150 pct and 2.000 maximum at 150 pct and 0.100 minimum at 200 pct and 0.700 maximum at 200 pct and 0.030 minimum at 300 pct and 0.200 maximum at 300 pct
-
Inclosure Protection Type For Which Designed
dustproof and explosion proof and fungus resistant and moisture resistant
-
Thread Series Designator
unef
-
Center To Center Distance Between Terminals Parallel To Width
0.615 inches minimum and 0.635 inches maximum
-
Pole Quantity
2
-
Mounting Facility Type And Quantity
thd bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes dc
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc
-
Circuit Protection Type
overcurrent
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip
-
Terminal Type And Quantity
4 wire hook