NSN: 5925-01-033-0454
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Pitch Diameters
+0.1177/+0.1214 inches
-
Body Length
2.510 inches maximum
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.046 inches minimum and 2.078 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Boss Height
0.140 inches nominal
-
Mounting Facility Type And Quantity
6 threaded hole
-
Special Handling Feature
magnetic
-
Trip Release Method
magnetic all locations
-
Manual Actuator Type And Quantity
3 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Nominal Thread Size
0.138 inches
-
Switch Location And Position Designation
internal at pole one
-
~1
and vibration resistant
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant and salt spray proof and shock resistant
-
Switch Terminal Type
knife blade
-
Switch Current Rating And Type In Amps
10.0 ac and 2.0 dc
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Terminal Type And Quantity
6 threaded stud
-
Specification/Standard Data
81349-mil-c-55629/6 government specification
-
Internal Trip Release Configuration
series trip all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.130 minimum at 200 pct and 1.600 maximum at 200 pct all locations
-
Frequency In Hertz
60.0
-
Test Data Document
81349-mil-c-55629 specification
-
Thread Series Designator
unc
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Auxiliary Switch Function And Quantity
1 alarm
-
Body Style
8c multipole-multiple actuator type
-
Body Width
2.205 inches minimum and 2.285 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.660 inches minimum and 1.960 inches maximum
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
2.553 inches maximum
-
Pole Quantity
3
-
Arc Quenching Method
magnetic blowout
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0