NSN: 5925-01-033-1983

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Body Style

    1b multipole-single actuator type

  • Bushing Length

    0.380 inches maximum

  • Body Length

    1.562 inches maximum

  • Body Width

    1.281 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.860 inches minimum and 0.890 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    between pole one and two

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.375 inches

  • Switch Terminal Type

    pin

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Frequency In Hertz

    50.0 or 60.0 all locations

  • Iii Unpackaged Unit Weight

    3.600 ounces

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Width

    0.610 inches minimum and 0.640 inches maximum

  • Iii Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Iii Nonturn Device Radius

    0.610 inches minimum and 0.640 inches maximum

  • Iii Nonturn Device Diameter

    0.235 inches minimum and 0.265 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Pole Quantity

    2

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.800 minimum at 200 pct and 8.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    4 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...