NSN: 5925-01-034-5225
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations and 240.0 ac all locations
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Terminal Type And Quantity
5 wire hook
-
Reset Method
manual
-
Maximum Continuous Load Current Rating Per Pole
8.5 amperes ac first location and 17.0 amperes ac second location
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 maximum at 200 pct first location
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
0.860 inches minimum and 0.890 inches maximum
-
Nonturn Device Location
at 3 oclock and at 9 oclock
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Internal Trip Release Configuration
series trip second location
-
Manual Actuator Type And Quantity
1 toggle
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.090 minimum at 200 pct first location and 0.090 minimum at 200 pct second location and 0.600 maximum at 200 pct second location
-
Maximum Continuous Load Current Rating Per Pole
17.0 amperes ac first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac all locations and 300.0 ac all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Arc Quenching Method
magnetic blowout
-
Unpackaged Unit Weight
3.600 ounces
-
Fragility Factor
moderately rugged
-
Frequency In Hertz
47.0 all locations or 420.0 all locations
-
Body Length
1.562 inches maximum
-
Internal Trip Release Configuration
shunt trip first location
-
Center To Center Distance Between Terminals Parallel To Width
0.610 inches minimum and 0.640 inches maximum
-
Thread Series Designator
unef
-
Body Width
1.281 inches maximum
-
Inclosure Protection Type For Which Designed
hermetically sealed and shock resistant and vibration resistant
-
Bushing Length
0.380 inches maximum
-
Nonturn Device Diameter
0.235 inches minimum and 0.265 inches maximum
-
Nonturn Device Radius
0.610 inches minimum and 0.640 inches maximum
-
Nonturn Device Length
0.130 inches nominal