NSN: 5925-01-034-6648

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac first location

  • Terminal Type And Quantity

    4 tab, solder lug

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 200 pct first location and 1.000 maximum at 200 pct first location

  • Inclosure Protection Type For Which Designed

    shockproof and corrosion resistant and moisture resistant and vibrationproof

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Surface To Terminal End Distance

    2.390 inches maximum

  • Body Length

    2.590 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Manual Actuator Type And Quantity

    1 rotary

  • Body Style

    multipole-single actuator type

  • Actuator Position Designation

    at pole two

  • Maximum Continuous Load Current Rating Per Pole

    50.0 milliamperes dc second location

  • Internal Trip Release Configuration

    series trip first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations and 1000.0 dc all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Precious Material

    silver

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Unpackaged Unit Weight

    4.400 ounces

  • Pole Quantity

    2

  • Internal Trip Release Configuration

    relay trip second location

  • Circuit Protection Type

    overcurrent all locations

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Body Width

    1.515 inches nominal

  • Bushing Length

    0.130 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.010 minimum at 200 pct second location and 0.040 maximum at 200 pct second location

  • Operating Voltage Type And Rating Per Pole In Volts

    20.0 dc second location

  • Precious Material And Location

    contact and terminal surfaces silver

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac first location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...