NSN: 5925-01-038-5409

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    2.475 inches nominal

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Body Width

    0.750 inches maximum

  • Unpackaged Unit Weight

    3.700 ounces

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac single location

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Special Handling Feature

    magnetic

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Boss Height

    0.150 inches nominal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Length

    1.940 inches nominal

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt water resistant and shock resistant and vibration resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct single location and 22.000 maximum at 200 pct single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...