NSN: 5925-01-040-7978
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
8c multipole-multiple actuator type
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Width
0.995 inches minimum and 1.057 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.995 inches minimum and 1.057 inches maximum
-
Boss Height
0.209 inches minimum and 0.229 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Maximum Continuous Load Current Rating Per Pole
100.0 amperes dc second location
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 dc second location
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
7500.0 dc second location
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
External Actuator Linkage Arrangement
one and two linked
-
Internal Trip Release Configuration
series trip first location
-
Internal Trip Release Configuration
shunt trip second location
-
Terminal Type And Quantity
4 threaded stud
-
Body Length
5.769 inches minimum and 5.831 inches maximum
-
Body Width
2.041 inches minimum and 2.103 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
3.516 inches minimum and 3.578 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.516 inches minimum and 3.578 inches maximum
-
Fragility Factor
moderately rugged
-
Mounting Surface To Terminal End Distance
3.172 inches minimum and 3.296 inches maximum
-
Pole Quantity
2
-
Mounting Facility Type And Quantity
4 threaded hole
-
Storage Type
general purpose warehouse
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac first location
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0
-
Manual Actuator Type And Quantity
2 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct all locations
-
Frequency In Hertz
60.0
-
Thread Series Designator
unc