Technical Characteristics

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct and 1.500 maximum at 200 pct

  • Switch Location And Position Designation

    internal at pole one

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay

  • Circuit Protection Type

    overcurrent

  • Operating Voltage Type And Rating Per Pole In Volts

    65.0 dc

  • Maximum Continuous Load Current Rating Per Pole

    8.0 amperes dc

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Thread Series Designator

    unc

  • Switch Current Rating And Type In Amps

    10.0 ac and 5.0 dc

  • Switch Terminal Type

    tab,solder lug

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Method

    magnetic-hydraulic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Arc Quenching Method

    air

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Fragility Factor

    moderately rugged

  • Switch Contact Arrangement

    single pole,double throw

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Body Style

    single pole type

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...