NSN: 5925-01-044-5507

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.055 minimum at 200 pct single location and 0.950 maximum at 200 pct single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location and 50.0 dc single location

  • ~1

    data on certain environmental and performanc

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches minimum and 0.906 inches maximum

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Terminal Type And Quantity

    2 wire hook

  • Trip Release Method

    magnetic single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac single location and 500.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location and 20.0 amperes dc single location

  • Thread Series Designator

    unef

  • Mounting Surface To Terminal End Distance

    1.669 inches minimum and 1.700 inches maximum

  • Body Style

    single pole type

  • Frequency In Hertz

    400.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Case Material

    metal

  • Pole Quantity

    1

  • Body Width

    0.594 inches minimum and 0.625 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Specification/Standard Data

    81349-mil-c-39019/1 government specification

  • Body Length

    1.531 inches minimum and 1.562 inches maximum

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...