NSN: 5925-01-044-9566

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    11b multipole-single actuator type

  • Body Length

    5.844 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

  • Pole Quantity

    2

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    2 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.164 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.500 minimum at 200 pct and 7.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Thread Series Designator

    unc

  • Body Width

    2.063 inches nominal

  • Body Height

    2.609 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    5.437 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Boss Height

    0.218 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    6.0 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • External Actuator Linkage Arrangement

    one and two linked

  • Terminal Type And Quantity

    4 screw

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...