NSN: 5925-01-050-1182

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    metal

  • Nonturn Device Radius

    0.625 inches nominal

  • Body Style

    multipole-single actuator type

  • Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Switch Contact Arrangement

    single pole, double throw

  • Actuator Position Designation

    at pole two

  • Trip Release Method

    magnetic all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations and 500.0 dc all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Switch Location And Position Designation

    internal at pole three

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Bushing Length

    0.280 inches minimum and 0.380 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Nonturn Device Diameter

    0.250 inches nominal

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt spray proof and fungus resistant and vibration resistant

  • Fragility Factor

    moderately rugged

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct all locations and 6.000 maximum at 200 pct all locations

  • Terminal Type And Quantity

    6 wire hook

  • Center To Center Distance Between Terminals Parallel To Width

    0.687 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Thread Series Designator

    unef

  • Switch Terminal Type

    pin

  • Frequency In Hertz

    400.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Body Length

    1.562 inches maximum

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac all locations and 10.0 amperes dc all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    1.937 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...