NSN: 5925-01-051-3266
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Storage Type
general purpose warehouse
-
Mounting Facility Type And Quantity
3 clip
-
Reset Method
manual
-
Maximum Continuous Load Current Rating Per Pole
90.0 amperes ac all locations
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
3
-
Fragility Factor
moderately rugged
-
Case Material
plastic
-
Body Length
6.250 inches nominal
-
Trip Delay Time In Seconds Per Rated Continuous Current
360.000 maximum at 200 pct all locations
-
Body Width
2.230 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Body Height
2.650 inches nominal
-
Frequency In Hertz
60.0 all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations
-
Manual Actuator Type And Quantity
1 toggle
-
Boss Height
0.250 inches nominal
-
Body Style
multipole-single actuator type
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Center To Center Distance Between Terminals Parallel To Width
0.780 inches nominal
-
Trip Release Ambient Temp Rating
50.0 deg celsius nominal all locations
-
Actuator Position Designation
at pole two
-
Terminal Type And Quantity
3 clip and 3 compression
-
Trip Release Method
thermal-magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations