NSN: 5925-01-056-7608
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Length
2.000 inches minimum and 2.127 inches maximum
-
Inclosure Protection Type For Which Designed
general purpose
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.687 inches minimum and 0.813 inches maximum
-
Body Width
2.187 inches minimum and 2.313 inches maximum
-
Manual Actuator Type And Quantity
3 toggle
-
Trip Release Duty Cycle
continuous third location
-
Case Material
plastic
-
Fragility Factor
moderately rugged
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Unpackaged Unit Weight
10.000 ounces
-
Trip Release Characteristic
instantaneous third location and time delay third location
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Boss Height
0.062 inches minimum and 0.188 inches maximum
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
150.0 ac nominal third location
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Mounting Surface To Terminal End Distance
2.375 inches minimum and 2.501 inches maximum
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic-hydraulic all locations
-
Body Style
multipole-multiple actuator type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Internal Trip Release Configuration
series trip first location
-
Trip Release Characteristic
time delay first location
-
Mounting Facility Type And Quantity
6 threaded hole
-
Terminal Type And Quantity
8 threaded stud
-
Internal Trip Release Configuration
series trip second location
-
Internal Trip Release Configuration
series/relay trip third location
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay second location
-
Maximum Continuous Load Current Rating Per Pole
40.0 amperes ac all locations
-
Body Length
2.437 inches minimum and 2.563 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.000 inches minimum and 2.127 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.687 inches minimum and 0.813 inches maximum