NSN: 5925-01-057-7398

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.500 inches nominal

  • Body Width

    2.200 inches minimum and 2.280 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.140 inches nominal

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Special Handling Feature

    magnetic

  • Body Style

    8c multipole-multiple actuator type

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Mounting Surface To Terminal End Distance

    2.409 inches minimum and 2.533 inches maximum

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    12.0 dc third location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac first location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc third location

  • Circuit Protection Type

    overcurrent second location

  • Circuit Protection Type

    undervoltage third location

  • Trip Release Characteristic

    time delay first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    130.0 all locations

  • Manual Actuator Type And Quantity

    3 toggle

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct first location and 2.000 maximum at 200 pct

  • Frequency In Hertz

    400.0 first location

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac second location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac first location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac second location

  • Circuit Protection Type

    overcurrent first location

  • Trip Release Method

    magnetic-hydraulic all locations

  • Trip Release Characteristic

    instantaneous third location

  • Trip Release Characteristic

    time delay second location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct second location and 2.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Frequency In Hertz

    400.0 second location

  • Unpackaged Unit Weight

    9.500 ounces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...