NSN: 5925-01-061-7108

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Switch Current Rating And Type In Amps

    10.0 ac

  • Frequency In Hertz

    60.0

  • Unpackaged Unit Weight

    2.700 pounds

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.550 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Switch Contact Arrangement

    single pole,double throw

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    4

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    250.0 milliamperes ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Ultimate Trip Time Per Pole In Seconds

    800.000 maximum

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    4 toggle

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one,two,three,and four linked

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    external at pole one

  • Body Length

    5.125 inches nominal

  • Body Width

    4.144 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.026 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.026 inches nominal

  • Boss Height

    0.220 inches nominal

  • Mounting Surface To Terminal End Distance

    3.550 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Features Provided

    high inrush protection

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    277.0 ac and 480.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Trip Release Method

    magnetic-hydraulic

  • Actuator Position Designation

    at each pole

  • Internal Trip Release Configuration

    series trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    70.000 minimum at 125 pct and 800.000 maximum at 125 pct and 20.000 minimum at 200 pct and 130.000 maximum at 200 pct and 4.000 minimum at 400 pct and 18.000 maximum at 400 pct and 0.012 minimum at 1000 pct and 0.080 maximum at 1000 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Terminal Type

    tab,solder lug

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Special Features

    anti-flashover barrier between poles

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    8 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...