Technical Characteristics

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Terminal Type And Quantity

    4 screw

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct all locations and 3.000 maximum at 200 pct all locations

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Continuous Load Current Rating Per Pole

    2.0 amperes ac second location

  • Nominal Thread Size

    0.138 inches

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    1.515 inches maximum

  • Frequency In Hertz

    60.0 single location

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac second location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3500.0 ac all locations

  • Inclosure Protection Type For Which Designed

    corrosion resistant and moisture resistant and shockproof and vibrationproof

  • Maximum Continuous Load Current Rating Per Pole

    4.0 amperes ac first location

  • Case Material

    plastic

  • Boss Height

    0.130 inches nominal

  • Fragility Factor

    moderately rugged

  • Trip Release Method

    magnetic single location

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.515 inches minimum and 1.545 inches maximum

  • Pole Quantity

    2

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.660 inches nominal

  • Unpackaged Unit Weight

    4.400 ounces

  • Thread Series Designator

    unc

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac first location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...