NSN: 5925-01-064-7823
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
2.490 inches minimum and 2.510 inches maximum
-
Body Width
2.240 inches minimum and 2.260 inches maximum
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
-
Iii Fragility Factor
moderately rugged
-
Pole Quantity
3
-
Iii Arc Quenching Method
magnetic blowout
-
Mounting Facility Type And Quantity
6 threaded hole
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Trip Release Method
magnetic-hydraulic all locations
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Time Per Pole In Seconds
10.000 minimum all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct and 0.600 minimum at 300 pct and 5.000 maximum at 300 pct and 0.300 minimum at 400 pct and 2.000 maximum at 400 pct and 0.005 minimum at 1000 pct and 0.040 maximum at 1000 pct all locations
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Thread Series Designator
unc
-
Terminal Type And Quantity
6 threaded stud
-
Body Style
8c multipole-multiple actuator type
-
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Boss Height
0.140 inches minimum and 0.160 inches maximum
-
Mounting Surface To Terminal End Distance
2.601 inches minimum and 2.621 inches maximum
-
Iii Storage Type
general purpose warehouse
-
Circuit Protection Type
overcurrent all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Reset Method
manual
-
Manual Actuator Type And Quantity
3 toggle
-
Actuator Position Designation
at each pole
-
Frequency In Hertz
50.0 or 60.0 all locations
-
Iii Unpackaged Unit Weight
12.750 ounces